Technical parameters:
Parameter CY-1200L Enteral feeding pump | |||
Conventional model | 15 d/ml infusion set 0.0ml/h~1200ml/h
20 d/ml infusion set 0.0ml/h~1200ml/h 60 d/ml infusion set 0.0ml/h~300ml/h Note:minimum resolution of setting flow rate is 0.1mL/h when rate is above 1000mL/h, the Resolution is 1mL/h. |
||
Drip Mode | 15 d/ml infusion set 0 d/min~300 d/min
20 d/ml infusion set 0 d/min~400 d/min 60 d/ml infusion set 0 d/min~300 d/min Note:The minimum resolution dripping speed Settings 1d/min. |
||
Accuracy | ≤±3%(Note:Under the condition of the benchmark test, using high elastic silicone iv path
accuracy after calibration and commissioning.) |
||
Bubble Detector | Ultrasonic detection method:Bubble above 25ul is detected | ||
Total Infusion Volume | 0.0ml-9999ml(0.1ml/h increment,1ml/h increment if over 1000ml/h) | ||
Volume Limit | 0.0ml-9999ml(0.1ml/h increment,1ml/h increment if over 1000ml/h) | ||
Occlusion | (H):800±200mmHg (106.7±26.7kPa)
(C):500±100mmHg (66.7±13.3kPa) (L):300±100mmHg (40.7±13.3kPa) |
||
History Record | These serial products can maximally store 4500 pieces of history records.
The record includes the following information: Date, flow rate, alarm data, total volume delivered, occlusion pressure and syringe brand and serial number. |
||
Alarm | Near empty alarm,Empty alarm,Door open alarm, Bubble alarm,limited value
reached alarm, AC power failure,Low battery alarm,Battery empty alarm,Remind alarm,Flow regulator or inlet valve closed alarm (optional) |
||
Power | Supply Voltage:AC100V~240V(±10%),Power Frequency: 50Hz-60Hz
Built-in Battery:DC15V Ni-MH battery(It can be replaced by lithium ion battery pack necessary.) Working time of battery:In case the battery is fully charged, the continuous working time can be up to 6 hours at the speed of 25ml/h. Maximum power:30VA;Note:Before the first use of this product, the battery must be charged while being shut down for more than 12 hours. |
||
Working Environment | Temperature:+5℃-+40℃
Relative humidity:20%-90% Environmental pressure:860hPa-1060hPa |
||
Transport And Storage Environment | Temperature:-20℃~+55℃;
Atmosphere Pressure:500hPa~1060hPa. products should be stored in the relative humidity in the range of 10% ~ 93%, no corrosion gas indoor and ventilated. |
||
Electric Safety Classification | Class I, CF type,Built-in battery,Continuous operation equipment | ||
Water Proof Level | IPX4 | ||
Net Weight | 1.6kg(include fastener) | ||
Dimension | 155mm*125mm*200mm | ||
Function | |||
Safety lock for PURGE/BOLUS
Standby function Preset occlusion detection pressure level (three levels) Preset Volume To Be Infused Audible and visual alarm (volume adjustable) RS232 interface History data memory |
Safety lock for flow rate adjust
Tube heating function Bolus release Inquiry of total infused volume Power indicator Vehicle Power Double CPU |
||
Advanced Function | |||
Adjust occlusion detection pressure
Adjust KVO rate |
Intelligent pressure test
Preset maximum value of flow rate Preset system time |