    Technical parameters:

     

    Parameter CY-1200L Enteral feeding pump
    Conventional model 15 d/ml infusion set               0.0ml/h~1200ml/h

    20 d/ml infusion set               0.0ml/h~1200ml/h

    60 d/ml infusion set               0.0ml/h~300ml/h

    Note:minimum resolution of setting flow rate is 0.1mL/h when rate is above 1000mL/h,

    the Resolution is 1mL/h.

    Drip Mode 15 d/ml infusion set               0 d/min~300 d/min

    20 d/ml infusion set               0 d/min~400 d/min

    60 d/ml infusion set               0 d/min~300 d/min    Note:The minimum resolution dripping

    speed Settings 1d/min.

    Accuracy ≤±3%(Note:Under the condition of the benchmark test, using high elastic silicone iv path

    accuracy after calibration and commissioning.)

    Bubble Detector Ultrasonic detection method:Bubble above 25ul is detected
    Total Infusion Volume 0.0ml-9999ml(0.1ml/h increment,1ml/h increment if over 1000ml/h)
    Volume Limit 0.0ml-9999ml(0.1ml/h increment,1ml/h increment if over 1000ml/h)
    Occlusion (H):800±200mmHg (106.7±26.7kPa)

    (C):500±100mmHg (66.7±13.3kPa)

    (L):300±100mmHg (40.7±13.3kPa)

    History Record These serial products can maximally store 4500 pieces of history records.

    The record includes the following information: Date, flow rate, alarm data, total volume

    delivered,   occlusion pressure and syringe brand and serial number.

    Alarm Near empty alarm,Empty alarm,Door open alarm, Bubble alarm,limited value

    reached alarm,

    AC power failure,Low battery alarm,Battery empty alarm,Remind alarm,Flow

    regulator or   inlet valve closed alarm (optional)

    Power Supply Voltage:AC100V~240V(±10%),Power Frequency: 50Hz-60Hz

    Built-in Battery:DC15V Ni-MH battery(It can be replaced by lithium ion battery pack

    necessary.)

    Working time of battery:In case the battery is fully charged, the continuous working time can

    be up to 6 hours at the speed of 25ml/h.

    Maximum power:30VA;Note:Before the first use of this product, the battery must be charged

    while being shut down for more than 12 hours.

    Working Environment Temperature:+5℃-+40℃

    Relative humidity:20%-90%

    Environmental pressure:860hPa-1060hPa

    Transport And Storage Environment Temperature:-20℃~+55℃;

    Atmosphere Pressure:500hPa~1060hPa.

    products should be stored in the relative humidity in the range of 10% ~ 93%,

    no corrosion gas   indoor and ventilated.

    Electric Safety Classification Class I, CF type,Built-in battery,Continuous operation equipment
    Water Proof Level IPX4
    Net Weight 1.6kg(include fastener)
    Dimension 155mm*125mm*200mm
    Function
    Safety lock for PURGE/BOLUS

    Standby function

    Preset occlusion detection pressure level (three levels)

    Preset Volume To Be Infused

    Audible and visual alarm (volume adjustable)

    RS232 interface

    History data memory

    Safety lock for flow rate adjust

    Tube heating function

    Bolus release

    Inquiry of total infused volume

    Power indicator

    Vehicle Power

    Double CPU

    Advanced Function
    Adjust occlusion detection pressure

    Adjust KVO rate

    Intelligent pressure test

    Preset maximum value of flow rate

    Preset system time