With our leading technology also as our spirit of innovation,mutual cooperation, benefits and development, we are going to build a prosperous future jointly with your esteemed company for Patient Bed For Home, , Ot Light Price, , Gynecological Examination Table Price, , Honesty is our principle, skilled procedure is our perform, service is our target, and customers' satisfaction is our long term!
Best-Selling Neonatal Incubator - 9000L+ Health Multipara Patient Monitoring System Devices – Annecy Detail:

Neonate Monitor

8.4″ Standard 5 Parameters

ECG, NIBP,SpO2,RESP, TEMP,HR

Neo ECG cable

NEO SpO2 sensor

NEO nibp cuff

 

Features &Benefits:

1.        10.4”,12.1”,15” color TFT display,

2.        Separated para board: ECG, NIBP, SpO2 board;

3.        Full touch-screen enables intuitive operation by clicking one the specific parameters or the waveform in real time, standard configuration includes the navigation knob.

4.        Real time S-T segment analysis, Drug Dose Calculation and ARR analysis;

5.        SpO2 Pitch Tone Variation and Drug Dose Calculation;

6.        Multi-display: Standard, Large font, Trend Coexis, OxyCRG dynamic

7.        Parameter waveform and characters color selectable

8.        Standby mode for Energy saving and suspend monitoring;

9.        7-lead ECG waveforms display in phase;

10.    Capture dynamic waveforms;

11.    Internal storage: 3600s full-disclosure waveform review;

12.    External storage: SD card slot enables memory extension;

13.    Built-in rechargeable lithium battery, and battery volume checking,

14.    AC power checking

15.    Efficient resistance to interference of defibrillator and HF knife;

16.    SINNOR F-6 SpO2 technology, VS Nellcor accuracy;

17.    Networking capacity and TCP/IP networking platform enable abundant future upgrade

18.    Time delay switch-off function keep the monitor data restart monitor;

19.    Complete and flexible mounting solution for transportation and in-patient monitoring

 

Standard parameters: 5-lead ECG, SpO2(F-5),NIBP, TEMP,RESP,PR,HR.

Optional: Touch Screen, Thermal Recorder, 3/12-lead ECG, 2/4-IBP,4-TEMP,2-SpO2, Nellcor/Masimo SpO2,BIS, Phaisein/ Respironics Multi-gas, ICG/CO, FHR, FM, TOCO,

 

Performance Specifications

Display:                          color TFT, 15”, Resolution:1024×768,

12”, 10.4” Resolution:1024×768,

Multi display selectable including:

Large-font display

Trend coexist display

OxyCRG dynamic view display.

Bed-to-bed view display

Trace:                8 waveforms(7 ECG, 1 SPO2 and 1 RESP)

Sweep speed:12.5mm/s,25mm/s,50mm/s

Indicator:             Power/battery indicator light

QRS beep and alarm sound

Battery:               Rechargeable lead acid cell, 12v/4AH

Max.24 hour for charging, 4 hours for continue working

Trend:             Parameter graphic and tabular trends:

5s/piece,8 hours;

1min/piece,168 hours(24h×7days)

5min/piece,1000 hours.

 

Storage:            NIBP: 1000 groups

Alarm: 200 groups

Full disclosure waveforms: 1 hour

Alarm:                    User-adjustable High, Medium and Low limits 3-level Audible and visual alarm

Networking:         Connected to central monitoring system

TCP/IP netting platform

Recorder:              Build-in, thermal array

Plethysmogram caveform:2 channels

Record mode: manual, on alarm, time-defined

Recording width: 50mm

Printing speed: 50mm/s

Recording type:         Frozen waveform record

NIBP recall record

Trend table record

Alarm record

Fixed -time record

 

 

Specifications

 

ECG:

 

Lead mode:                                5 –lead(R,L,F,N,C)

Lead selection :                        I,II,III,avR,avL,avF,V

Waveform:                          3 and 7 channel selectable

Gain selection:                        0.5mm/mv,1mm/mv,2mm/mv

Sweep speed:                          12.5mm/s;25mm/s;50mm/s

Heart rate range:               Adult: 15~300bpm;

Neonate:/pediatric:15~350bpm

Accuracy:                                   +1bpm or +1%,whichecer is greater

Resolution:                          1bpm

Filter:                                            surgery mode:1~20Hz

monitor model:0.5~40Hz

Diagnostic mode:0.05~130Hz

Scaling signal:                          1mv,+3%

Protection:                         withstand 4000VAC/50 voltage isolation against electrosurgical interference and defibrillation

Alarm range:                            15~350bpm

S-T segment detecton:

Measurement range:  2.0mV~+2.0mV

 

Alarm  Range:         -2.0mV~ +2.0mV

Accuracy:            -0.8mV ~+0.8Mv

Error:               +0.02Mv

 

Arrhythmia analysis:     YES

 

SPO2

Measurement range:        0~100%

Resolution:                1%

Accuracy:                 +2%(70-100%);0-69% unspecified

Alarm range               0~100%

Pluse Rate:                range:20~300bpm

Resolution:1bpm

Error:+1bpm or +2%,whichever is greater

 

NIBP

Method:                   Digital Automatic oscillometric

Operation mode :           Manual/Automatic/continuous

Auto measurement time:     Adjustable(1~480min)

Measurement Unit:         mmHg/Kpa selectable

Measurement types:         Systolic, Diastolic, Mean

Measurement tange:

Range of Systolic   pressure:   Adult: 40~270mmHg

Pediatric: 40~220mmHg

Neonate: 40~135mmHg

Range of mean pressure:     Adult: 20~235mmHg

Pediatric: 20~165mmHg

Neonate: 20~110mmHg

Range of diastolic pressure:   Adult: 10~215mmHg

Pediatric: 10~150mmHg

Neonate :10~100mmHg

Over-pressure protection:     Double safety protection

Resolution:                 1 mmHg

Alarm:                    Systolic.Diastolic,Mean

 

 

RESPIRATION

Method:                     Thoracic impedance

Measurement range:           Adult:7~120rpm;

Neonate/Pediatric:7~150rpm

Apnea alarm:                 YES,10~40s

Resolution:                   1rpm

Accuracy:                    +2rpm

 

 

TEMPERATURE

Compatible probe:             YSI or CYF

Measurement range:           5~50℃

Resolution :                   0.1℃

Accuracy:                    +0.1℃

Refreshing time:               about 1

Average measuring time:        <10s

 

 

Miscellaneous

 

Satety:              

Safety level: Class I, type CF

 

Dimendion and Weight

Dimendion:      440×430×450

G.Weight:        <9.0KS

 

Operation Environment

Temperature:    Working 0~+40℃

Transportation and storage –20~+60℃

Humidity:       working≤85%

Transportation and storage≤93%

Power:          AC 100-240,50/60Hz

Patient range:    Neonate,pediatric,and adult patients

 

 

Accessories supplies

(1) 5 lead ECG cable

(2) 1 spo2 probes

(3) 1 NIBP prbe

(4) 1 temp probe

(5)1 ground connecting liner

(6) Chest electrode (10pcs/set)


Product detail pictures:

Best-Selling Neonatal Incubator - 9000L+ Health Multipara Patient Monitoring System Devices – Annecy detail pictures

Best-Selling Neonatal Incubator - 9000L+ Health Multipara Patient Monitoring System Devices – Annecy detail pictures

Best-Selling Neonatal Incubator - 9000L+ Health Multipara Patient Monitoring System Devices – Annecy detail pictures


Related Product Guide:

As a way to provide you advantage and enlarge our organization, we even have inspectors in QC Crew and guarantee you our greatest assistance and product or service for Best-Selling Neonatal Incubator - 9000L+ Health Multipara Patient Monitoring System Devices – Annecy , The product will supply to all over the world, such as: Estonia, Swaziland, British, To let customers be more confident in us and get the most comfortable service, we run our company with honesty, sincerity and best quality . We firmly believe that it is our pleasure to help customers to run their business more successfully, and that our experienced advice and service can lead to more suitable choice for the customers.
  • A good manufacturers, we have cooperated twice, good quality and good service attitude.
    5 Stars By Raymond from UAE - 2018.07.26 16:51
    The sales person is professional and responsible, warm and polite, we had a pleasant conversation and no language barriers on communication.
    5 Stars By Agatha from Indonesia - 2018.09.19 18:37

    Send your message to us:

    Write your message here and send it to us

    Send your message to us:

    Write your message here and send it to us