    Specification:

    1.12.1inch,800*600dpi,color TFT display;

    2.Separated Alarm and beep sound seting;

    3.Separated module:Main board+Parameter module(ECG,NIBP, Sp02);

    4.Display brightness adjustable;

    5.Real time S-T segment analysis,and ARR analysis;

    6.Sp02 Pitch Tone Variation and Drug Dose Calculation;

    7.Parameter waveform and characters color selectable;

    8.Multi-display:Standard,large fondt,Trend Coexis,OxyCRG dynamic

    9.Standby mode for power saving and suspend monitoring;

    10.5-lead ECG waveforms display in phase;

    11.capture dynamic waveforms and history waveforms review;

    12.VGA output;

    13.Built-in rechargeable lithium battery 4 hours,and battery volume checking.

    14.Efficient resistance to interference of defibrillator and HF knife;

    15.SD card memory and USB data output;

    16.TCP/IP networking platform enable abundant future upgrade&CMS;

    17.Complete and flexible mounting solution for transportation and in-patient mniotring

    PERFORMANCE SPECIFICATION

     

    Display:                          color TFT, 15”, Resolution:1024×768,

    12”, 10.4” Resolution:1024×768,

    Multi display selectable including:

    Large-font display

    Trend coexist display

    OxyCRG dynamic view display.

    Bed-to-bed view display

    Trace:                8 waveforms(7 ECG, 1 SPO2 and 1 RESP)

    Sweep speed:12.5mm/s,25mm/s,50mm/s

    Indicator:             Power/battery indicator light

    QRS beep and alarm sound

    Battery:               Rechargeable lead acid cell, 12v/4AH

    Max.24 hour for charging, 4 hours for continue working

    Trend:             Parameter graphic and tabular trends:

    5s/piece,8 hours;

    1min/piece,168 hours(24h×7days)

    5min/piece,1000 hours.

     

    Storage:            NIBP: 1000 groups

    Alarm: 200 groups

    Full disclosure waveforms: 1 hour

    Alarm:                    User-adjustable High, Medium and Low limits 3-level Audible and visual alarm

    Networking:         Connected to central monitoring system

    TCP/IP netting platform

    Recorder:              Build-in, thermal array

    Plethysmogram caveform:2 channels

    Record mode: manual, on alarm, time-defined

    Recording width: 50mm

    Printing speed: 50mm/s

    Recording type:         Frozen waveform record

    NIBP recall record

    Trend table record

    Alarm record

    Fixed -time record

    SPECIFICATION

    Specifications

     

    ECG:

     

    Lead mode:                                5 –lead(R,L,F,N,C)

    Lead selection :                        I,II,III,avR,avL,avF,V

    Waveform:                          3 and 7 channel selectable

    Gain selection:                        0.5mm/mv,1mm/mv,2mm/mv

    Sweep speed:                          12.5mm/s;25mm/s;50mm/s

    Heart rate range:               Adult: 15~300bpm;

    Neonate:/pediatric:15~350bpm

    Accuracy:                                   +1bpm or +1%,whichecer is greater

    Resolution:                          1bpm

    Filter:                                            surgery mode:1~20Hz

    monitor model:0.5~40Hz

    Diagnostic mode:0.05~130Hz

    Scaling signal:                          1mv,+3%

    Protection:                         withstand 4000VAC/50 voltage isolation against electrosurgical interference and defibrillation

    Alarm range:                            15~350bpm

    S-T segment detecton:

    Measurement range:  2.0mV~+2.0mV

     

    Alarm  Range:         -2.0mV~ +2.0mV

    Accuracy:            -0.8mV ~+0.8Mv

    Error:               +0.02Mv

     

    Arrhythmia analysis:     YES

     

    SPO2

    Measurement range:        0~100%

    Resolution:                1%

    Accuracy:                 +2%(70-100%);0-69% unspecified

    Alarm range               0~100%

    Pluse Rate:                range:20~300bpm

    Resolution:1bpm

    Error:+1bpm or +2%,whichever is greater

     

    NIBP

    Method:                   Digital Automatic oscillometric

    Operation mode :           Manual/Automatic/continuous

    Auto measurement time:     Adjustable(1~480min)

    Measurement Unit:         mmHg/Kpa selectable

    Measurement types:         Systolic, Diastolic, Mean

    Measurement tange:

    Range of Systolic   pressure:   Adult: 40~270mmHg

    Pediatric: 40~220mmHg

    Neonate: 40~135mmHg

    Range of mean pressure:     Adult: 20~235mmHg

    Pediatric: 20~165mmHg

    Neonate: 20~110mmHg

    Range of diastolic pressure:   Adult: 10~215mmHg

    Pediatric: 10~150mmHg

    Neonate :10~100mmHg

    Over-pressure protection:     Double safety protection

    Resolution:                 1 mmHg

    Alarm:                    Systolic.Diastolic,Mean

     

     

    RESPIRATION

    Method:                     Thoracic impedance

    Measurement range:           Adult:7~120rpm;

    Neonate/Pediatric:7~150rpm

    Apnea alarm:                 YES,10~40s

    Resolution:                   1rpm

    Accuracy:                    +2rpm

     

     

    TEMPERATURE

    Compatible probe:             YSI or CYF

    Measurement range:           5~50℃

    Resolution :                   0.1℃

    Accuracy:                    +0.1℃

    Refreshing time:               about 1

    Average measuring time:        <10s

     

     

    Miscellaneous

     

    Satety:              

    Safety level: Class I, type CF

     

    Dimendion and Weight

    Dimendion:      440×430×450

    G.Weight:        <9.0KS

     

    Operation Environment

    Temperature:    Working 0~+40℃

    Transportation and storage –20~+60℃

    Humidity:       working≤85%

    Transportation and storage≤93%

    Power:          AC 100-240,50/60Hz

    Patient range:    Neonate,pediatric,and adult patients

     

     

    Accessories supplies

    (1) 5 lead ECG cable

    (2) 1 spo2 probes

    (3) 1 NIBP prbe

    (4) 1 temp probe

    (5)1 ground connecting liner

    (6) Chest electrode (10pcs/set)