• 9000V Bedside Remote Patient Monitoring Devices

9000V Bedside Remote Patient Monitoring Devices

Short Description:

Best selling Monitor with competitive prices

It  can be used under various kinds of severe environment to meet demand of medical agents such as troops and hospital, etc during emergency treatment, first aid and transportation in the field.


  • Service time: 24 hours
  • Min order: 1PCS
  • Sales mode: Wholesale
  • Product Detail

    Product Tags

    2

    3

    Bedside Monitor

    12.1 "Standard 5 Parameters

    ECG, NIBP,SpO2,RESP, TEMP,HR

     

    Features &Benefits:

    1.        10.4”,12.1”,15” color TFT display,

    2.        Separated para board: ECG, NIBP, SpO2 board;

    3.        Full touch-screen enables intuitive operation by clicking one the specific parameters or the waveform in real time, standard configuration includes the navigation knob.

    4.        Real time S-T segment analysis, Drug Dose Calculation and ARR analysis;

    5.        SpO2 Pitch Tone Variation and Drug Dose Calculation;

    6.        Multi-display: Standard, Large font, Trend Coexis, OxyCRG dynamic

    7.        Parameter waveform and characters color selectable

    8.        Standby mode for Energy saving and suspend monitoring;

    9.        7-lead ECG waveforms display in phase;

    10.    Capture dynamic waveforms;

    11.    Internal storage: 3600s full-disclosure waveform review;

    12.    External storage: SD card slot enables memory extension;

    13.    Built-in rechargeable lithium battery, and battery volume checking,

    14.    AC power checking

    15.    Efficient resistance to interference of defibrillator and HF knife;

    16.    SINNOR F-6 SpO2 technology, VS Nellcor accuracy;

    17.    Networking capacity and TCP/IP networking platform enable abundant future upgrade

    18.    Time delay switch-off function keep the monitor data restart monitor;

    19.    Complete and flexible mounting solution for transportation and in-patient monitoring

    Standard parameters: 5-lead ECG, SpO2(F-5),NIBP, TEMP,RESP,PR,HR.

    Optional: Touch Screen, Thermal Recorder, 3/12-lead ECG, 2/4-IBP,4-TEMP,2-SpO2, Nellcor/Masimo SpO2,BIS, Phaisein/ Respironics Multi-gas, ICG/CO, FHR, FM, TOCO,

     

    Performance Specifications

    Display:                          color TFT, 15”, Resolution:1024×768,

    12”, 10.4” Resolution:1024×768,

    Multi display selectable including:

    Large-font display

    Trend coexist display

    OxyCRG dynamic view display.

    Bed-to-bed view display

    Trace:                8 waveforms(7 ECG, 1 SPO2 and 1 RESP)

    Sweep speed:12.5mm/s,25mm/s,50mm/s

    Indicator:             Power/battery indicator light

    QRS beep and alarm sound

    Battery:               Rechargeable lead acid cell, 12v/4AH

    Max.24 hour for charging, 4 hours for continue working

    Trend:             Parameter graphic and tabular trends:

    5s/piece,8 hours;

    1min/piece,168 hours(24h×7days)

    5min/piece,1000 hours.

     

    Storage:            NIBP: 1000 groups

    Alarm: 200 groups

    Full disclosure waveforms: 1 hour

    Alarm:                    User-adjustable High, Medium and Low limits 3-level Audible and visual alarm

    Networking:         Connected to central monitoring system

    TCP/IP netting platform

    Recorder:              Build-in, thermal array

    Plethysmogram caveform:2 channels

    Record mode: manual, on alarm, time-defined

    Recording width: 50mm

    Printing speed: 50mm/s

    Recording type:         Frozen waveform record

    NIBP recall record

    Trend table record

    Alarm record

    Fixed -time record

     

     

    Specifications

     

    ECG:

     

    Lead mode:                                5 –lead(R,L,F,N,C)

    Lead selection :                        I,II,III,avR,avL,avF,V

    Waveform:                          3 and 7 channel selectable

    Gain selection:                        0.5mm/mv,1mm/mv,2mm/mv

    Sweep speed:                          12.5mm/s;25mm/s;50mm/s

    Heart rate range:               Adult: 15~300bpm;

    Neonate:/pediatric:15~350bpm

    Accuracy:                                   +1bpm or +1%,whichecer is greater

    Resolution:                          1bpm

    Filter:                                            surgery mode:1~20Hz

    monitor model:0.5~40Hz

    Diagnostic mode:0.05~130Hz

    Scaling signal:                          1mv,+3%

    Protection:                         withstand 4000VAC/50 voltage isolation against electrosurgical interference and defibrillation

    Alarm range:                            15~350bpm

    S-T segment detecton:

    Measurement range:  2.0mV~+2.0mV

     

    Alarm  Range:         -2.0mV~ +2.0mV

    Accuracy:            -0.8mV ~+0.8Mv

    Error:               +0.02Mv

     

    Arrhythmia analysis:     YES

     

    SPO2

    Measurement range:        0~100%

    Resolution:                1%

    Accuracy:                 +2%(70-100%);0-69% unspecified

    Alarm range               0~100%

    Pluse Rate:                range:20~300bpm

    Resolution:1bpm

    Error:+1bpm or +2%,whichever is greater

     

    NIBP

    Method:                   Digital Automatic oscillometric

    Operation mode :           Manual/Automatic/continuous

    Auto measurement time:     Adjustable(1~480min)

    Measurement Unit:         mmHg/Kpa selectable

    Measurement types:         Systolic, Diastolic, Mean

    Measurement tange:

    Range of Systolic   pressure:   Adult: 40~270mmHg

    Pediatric: 40~220mmHg

    Neonate: 40~135mmHg

    Range of mean pressure:     Adult: 20~235mmHg

    Pediatric: 20~165mmHg

    Neonate: 20~110mmHg

    Range of diastolic pressure:   Adult: 10~215mmHg

    Pediatric: 10~150mmHg

    Neonate :10~100mmHg

    Over-pressure protection:     Double safety protection

    Resolution:                 1 mmHg

    Alarm:                    Systolic.Diastolic,Mean

     

     

    RESPIRATION

    Method:                     Thoracic impedance

    Measurement range:           Adult:7~120rpm;

    Neonate/Pediatric:7~150rpm

    Apnea alarm:                 YES,10~40s

    Resolution:                   1rpm

    Accuracy:                    +2rpm

     

     

    TEMPERATURE

    Compatible probe:             YSI or CYF

    Measurement range:           5~50℃

    Resolution :                   0.1℃

    Accuracy:                    +0.1℃

    Refreshing time:               about 1

    Average measuring time:        <10s

     

     

    Miscellaneous

     

    Satety:              

    Safety level: Class I, type CF

     

    Dimendion and Weight

    Dimendion:      440×430×450

    G.Weight:        <9.0KS

     

    Operation Environment

    Temperature:    Working 0~+40℃

    Transportation and storage –20~+60℃

    Humidity:       working≤85%

    Transportation and storage≤93%

    Power:          AC 100-240,50/60Hz

    Patient range:    Neonate,pediatric,and adult patients

     

     

    Accessories supplies

    (1) 5 lead ECG cable

    (2) 1 spo2 probes

    (3) 1 NIBP prbe

    (4) 1 temp probe

    (5)1 ground connecting liner

    (6) Chest electrode (10pcs/set)